EU MDR SSCP2026 Field Guide

Who writes it, what it holds, and who uploads it — with the SSCP discipline you need.

Mandatory
Art 32
Handover
2026-4
Version
Layperson

Sourced from verified 2026 publications.

Download the guide

Enter your work email and we'll send the PDF straight to your inbox.

Professional review is required before business use. See our privacy policy.

What's inside

Two pages, zero fluff

Every figure in this guide traces to a named source — verified 2026 publications.

Who writes it

Who writes it: Article 32 duties, NB validation, and the layperson version with readability testing.

What it holds

What it holds: identification, clinical story, and evidence — the mandatory content set.

Who uploads it

Who uploads it: the MDCG 2026-4 handover, the Basic UDI-DI tick, and the label/IFU mention.

Complete guide

The guide in full

Every section of the PDF on one page. Use the form above to keep a copy.

1. Who writes it

  • For implantable devices and class III devices (other than custom-made or investigational devices), the manufacturer draws up the summary of safety and clinical performance (MDR Article 32(1)).
  • The draft is part of the conformity-assessment documentation and is validated by the notified body. After validation, the NB historically uploaded it to EUDAMED — MDCG 2026-4 is revising the handover: the manufacturer now uploads the master version and translations (per Article 29(4)), while the NB indicates the validated SSCP(s) by ticking Basic UDI-DI boxes when the certificate is registered or linked.
  • Write it clear to the intended user and, if relevant, to the patient — in a clear, non-promotional format. If the device is implanted or used directly by patients, a layperson version in plain language is required, with readability validation that the NB will scrutinize.

2. What it holds

  • Identification: the device and the manufacturer, including the Basic UDI-DI and, if already issued, the SRN.
  • Clinical story: intended purpose, indications, contraindications, target populations; device description (previous generations/variants, accessories); possible diagnostic or therapeutic alternatives; harmonised standards and common specifications applied.
  • Evidence: summary of the clinical evaluation (Annex XIV) and relevant PMCF information; residual risks, undesirable effects, warnings, and precautions; suggested user profile and training.

3. Who uploads it

  • Once validated, the SSCP is made available to the public via EUDAMED — it is the only device document deliberately written for healthcare professionals, patients, and regulators alike.
  • The manufacturer must mention on the label or IFU where the summary is available — a small labeling duty that competent authorities check.
  • MDCG 2019-9 Rev.1 (NB-only upload) is being revised under 2026-4: confirm in your SOPs who uploads and who ticks the Basic UDI-DI boxes — statute, old guidance, and the 2026-4 handover are three different instruments.

Sources & scope

  • meddeviceguide.com, MDCG 2026-4: Who Uploads SSCP and SSP to EUDAMED.
  • namsa.com, Summary of Safety and Clinical Performance (SSCP) MDR.
  • tuv-sud.com, Chapter III (MDR): Identification and traceability.

This guide is market-access intelligence, not regulatory or legal advice. SSCP rules, MDCG guidance, and EUDAMED readiness change — professional review is required before business use.

Market Access Strategy Session

Class III on your 2026 roadmap? Start with the full picture.

A Market Access Strategy Session maps your EU route — SSCP planning, clinical evidence strategy, and EUDAMED readiness.

Professional review is required before business use.